⇒ Triple Functionalities
-
PD Detection, Analysis and Diagnostics
-
History Data Display and Analysis
-
Cable PD Location Detection
⇒ Complex PD Analysis, Versatile
-
Suitable for complex and difficult PD analysis
-
Suitable for detecting and measuring PD on almost any type of power equipment
|
|
Function I: PD Detection, Analysis and Diagnostic
- Non-intrusive test on live power equipment, no need to cut-off electricity for testing, no restriction on voltage level.
- Records whole waveform of each discharge pulse received, no omission.
- Accurately identifies PD by extracting features of the received signals in multiple domains and discerning PD from interference with with smart algorithms.
- Able to identify multiple PD sources as well as weak, sporadic and intermittent discharges.
- Self calibration and verification capability.
- Multi input channels, adapting to various sensors (HFCT, TEV, UHF, WBAnt, AE) and detection methods.
- Multi measuring scopes, large dynamic range.
- Automatically detecting noise level and setting denoise threshold, extracting PD signals from noise.
- Analogous filters + digital filters, enables signal analysis in multiple bands.
- Ultra low noise circuitry, multiple layers of noise filtering and suppression.
|
|
Function II: History Data Display and Analysis
-
Retrieves and displays
the waveform and features of each recorded discharge signal, completely re-display the discharge phenomenon.
-
Side-by-side Comparison:
retrieves and compares the data captured on different power equipment, or on different positions of a same equipment, identifies the sources of the signals.
-
History Comparison:
retrieve and compare the data acquired and recorded at different times on a same power equipment, analyse the PD developing trend and speed, evaluate the insulation condition of the power equipment.
|
|
Function III: Cable PD Location Measurement
- Accurately measure the PD location along a cable in its live working condition, no need to cut-off power supply,overcome the shortcomings of Damped AC and Ultra-low Frequency measurements that require power outages.
- Long measuring distance, can measure PD location on a cable up to 2km or even longer with high accuracy.
|
|
Complex and difficult PD diagnostic,Versatile
|